Product Details:
Usage/Application | Automotive Industry |
Brand | KIKUSUI |
Part Number | PAT-T Series |
Display Type | LED |
Power | DC power supply |
Power Factor | 0.95 |
Output Power | 4kW to 40kW DC |
4 kW type can operate even with single-phase 200-volt input. (However, current is limited to about 75% of rated value.)
Standardly equipped with the RS-232C interface.
Supports USB/GPIB/LAN interface.(Factory option)
Controllable from Excel VBA and LabView with measuring instrument driver. The driver can be downloaded free at our web site.
Capacity can be expanded through parallel operation (up to five units of the same model).
Equipped with reliable output ON/OFF delay function during sequence operations.
Memory function (three sets of voltage/current)
Voltage/current monitor output
Status signal output
Remote sensing function
Protective functions (shutdown, as well as protection against overvoltage, overcurrent, overheating, input phase interruption, fan malfunction, sensing, and bleeder circuit overheating)
High noise resistance (for reassurance during car electronics testing)
Good maintainability, including easy fan replacement
3-phase 400V input available (8kw type)
The LAN interface applies to the LXI (LAN eXtensions for Instrumentation). If that interface is used, it is possible to control and monitor the power supply from a browser.
Applications:
Lifetime testing of headlights, etc
Performance and endurance testing of inverters for use in high-capacity air conditioners and motors
Performance and endurance testing of brushless motors for use in EPS, MG, and SG units
Performance testing of IPM, IGBT, and other power modules
Performance testing of starter motors
Additional Information:
Product Details:
Brand | KIKUSUI, JAPAN |
Series | PAD-LA SERIES |
Input Voltage | 36 |
Output Type | Multiple |
Power | Electric |
Output Voltage | 24V |
Use large LED monitor with high visibility for 4digits display
Output and Set Switch
Putting together of the mode setting switches
Built-in OCP circuit (Over Current Protection circuit)
Output Monitoring
Control Terminals
Technical Index:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Instrument |
Usage/Application | Electronic Instruments |
Part Number | PBZ- SERIES |
Brand | KIKUSUI |
Maximum Input Voltage | 230VAC |
Maximum Operating Temperature | 45 degree C |
Design | Compact |
Display Type | LED |
Series | PBZ Series |
Input Voltage | 220V AC |
Output Type | Bi-polar |
Output Voltage | +/- 80V, +/-60V, +/-40V, +/-20V |
Power Source | bipolar Power supply |
Additional Information:
Product Details:
Usage/Application | Lab./ Automotive industry |
Part Number | KIKUSUI PMX-Multi series |
Brand | KIKUSUI |
Input Voltage | 110 VAC - 230 VAC |
Output Type | Single, Triple, Dual |
Power | 30VDC - 60VDC |
Output Voltage | 48V |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Power Source | Electric |
Voltage | 220 V |
Frequency | 50-60 Hz |
Display Type | LCD |
Wavelength Ranges | 850 - 1625 nm |
Precision | 0.01 dBm |
Measuring Range | -70 to +6 dBm and -50 to +26 dBm |
Product Details:
Usage/Application | Electronic Instruments |
Design | Compact |
Display Type | Digital |
Series | PCR Series |
Input Voltage | 220V |
Output Voltage | 300V |
Features | compact AC + DC Power Supply |
Operating Ambient Temperature | 45 degree C |
Brand | Kiksui japan |
Available Range: Single phase 500 VA - 2 kVA, AC1 to 270V, 40 to 500Hz , DC+/-1.4 to +/-380V, PWM type
Compact design: Small enough to fit on your work desk. Only 214 X 124 X 350 mm. Weights only 6 kg and easy to carry (PCR500M).
Versatile output modes: Three modes (AC, DC, AC+DC) are available. The frequency range is up to 500 Hz.
Memory function: You can store and recall three combinations of settings for voltage and frequency on the main unit. By calling the memory during output, you can test the sudden changes of voltage or frequency.
Measurement functions: You can measure the voltage, current and power of AC and DC output, apparent power, reactive power, power factor, crest factor and current peak hold.
Various communication interface options: RS-232C is provided as standard. GPIB and USB are optional.
Analog interface: By incorporating an optional analog interface (EXO4-PCR-M), the output can be controlled by using external analog signals. Input DC signals can be used to change output AC voltage and boost input waveform.
Control using a PC: You can control the PCR-M Series through the standard RS-232C interface, the optional GPIB interface, or the optional USB interface. And by using the control software (Easy Controller for PCR-M) which comes with the PCR-M Series, you can easily set the parameters of the PCR-M Series and log the output measured values.
Additional Information:
Product Details:
Usage/Application | R&D, Lab., Testing |
Design | Compact |
Display Type | Digital |
Series | PCR-LE Series |
Input Voltage | 220 V/440 V AC |
Output Voltage | 300 VAC,424V DC |
Warranty | 1 year |
Operating Ambient Temperature | 0-45 degree C |
Brand | Kikusui, japan |
Additional Information: